0 to 480V AC, with an adjustable output frequency range up to 120Hz Common Models: For instance, the CIMR-K7H4015 is rated for 15 kW (approximately 20 HP) .
Not recommended. The K7’s overload rating is 110% for 60 seconds (variable torque), whereas constant torque drives (e.g., G7 or H7) provide 150% for 60 seconds. Using a K7 for a high-inertia conveyor will trip OC faults repeatedly.
The manual defines how to map inputs and outputs within the software environment to the physical hardware.
The Yaskawa K7 (part of the Sigma-7 series) represents a significant leap in motion control technology. This manual serves as your primary guide for maximizing the performance of these AC brushless servomotors. Introduction to the Yaskawa Sigma-7 (K7) yaskawa k7 manual
When the drive trips and the keypad displays an error code, the troubleshooting chapter is your primary resource. It provides lists of common fault displays (such as Overcurrent, Overvoltage, and Overheat), the likely causes, and the corrective actions you need to take. ⚙️ Key Technical Specifications to Keep in Mind
Drives contain high-voltage capacitors that remain charged after power is disconnected. Wait at least 10–15 minutes (check the manual for specific time) after turning off power.
Due to the age of the K7 series (discontinued in many regions in the mid-2000s), finding an official manual can be challenging. However, several reliable sources exist. 0 to 480V AC, with an adjustable output
Configures user units relative to encoder resolution. Pn210 Dependent on Ratio
When manually tailoring the drive's response characteristics, adjust the following parameters hierarchically: Operational Impact Speed Loop Gain (Kv)
Since "K7" is not a current flagship model number for Yaskawa inverters (drives), this write-up addresses the two most likely scenarios: the ** legacy K7 Series Hydraulic Servo Controllers** (often used in injection molding machines) and a possible confusion with the popular general-purpose drives. Using a K7 for a high-inertia conveyor will
Indicated by red LEDs on the module itself, signaling a short circuit or overvoltage. 6. Accessing the Official Documentation
: Disconnect the motor cable from terminals U, V, and W. Check phase-to-phase and phase-to-ground resistance using a megohmmeter. Inspect heat sink cooling fans for debris or mechanical seizure. A.410: Undervoltage
Proper installation is crucial for reliability. The manual offers detailed instructions:
Configuring the network module (e.g., Profibus, Modbus) involves setting the node address and baud rate as detailed in the technical documentation. 5. Troubleshooting the Yaskawa K7